Case Study #1 - Airport Runway Extension



THE SITUATION:
A stream of water presented an obstacle during a project involving the extension of an airports runway.

THE SOLUTION: A box culvert was buried sixty feet below the earths surface to effectively re-channel the stream beneath the runway.

Precast Application: Box Culvert

Precaster: Mack Industries

Regulatory Agency: FAA

ConSeal Products used:
(Click on a highlighted link to view more information about a product.)

CS-102 Butyl Rubber Sealant used for the primary seal inside the lap joints of the box culverts

CS-75 Water-Based Primer used to aid installation of the CS-102 joint sealant and CS-212 external joint wrap.

CS-212 External Joint Wrap used as an additional precaution to prevent possible soil and sediment erosion in the joint area

Applicable ASTM Standards:

ASTM C-887 Standard Specification for External Sealing Bands for Concrete Pipe, Manholes, and Precast Box Sections, Type III, Chemically-Bonded Adhesive Butyl Bands

ASTM C-990 Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants

ASTM C-798 Replaced in November 2000 by ASTM C-1433 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers

 
 